Re: No more CDJ crashes, but no more X-10

Posted By: Dan Butterfield <dan@b...>
Date: 7/11/1999 8:11p.m.

In Response To: Re: No more CDJ crashes, but no more X-10 (Colby Boles)

I may have spoken too soon on the no CDJ crashes post: since running CDJ for over a week on the new machine, I did finally experience an abort in MFC42.DLL similar to the ones I used to experience fairly regularly on the older slower machine. I strongly suspect in this case it was due to me holding down either the receiver volume change button or the VCR FF/REW button (my VCR does not have locking FF/REW modes) for a long time (for non-CDJ reasons), because I happened to check CDJ immediately after that and that's when I saw the crash.

It seems like a flood of data is causing this problem (I have my IR receiver set to 100ms sampling). Holding down the IR source for a long period of time probably causes some sort of buffer overflow. This would explain the intermittent nature, the increased occurance on a slower machine, and the fact that some people don't get the problem (probably don't have their IR receiver turned on, or don't use IR around the Slink-e much, or don't have prolonged periods of IR due to holding down a button).

Don't know if this helps at all, but you might try experimenting with prolonged IR. I just now experimented with holding down the FF button for my VCR (a Sony M20HF) for one minute. After I released the button, CDJ was frozen and not even responding to clicks on menus. I got a "Server busy" message, and a bunch of SendEx error 5's appeared in the Slink-e data window. After clicking on the "Server busy" message I got this failure:

CDJ caused an invalid page fault in
module MFC42.DLL at 0167:5f4040fd.
Registers:
EAX=000005d0 CS=0167 EIP=5f4040fd EFLGS=00010206
EBX=0044c21a SS=016f ESP=00fffbd4 EBP=00fffbe8
ECX=007ecc28 DS=016f ESI=008fe57c FS=385f
EDX=00000000 ES=016f EDI=008fe594 GS=0000
Bytes at CS:EIP:
83 78 f4 00 0f 8c 7c 7b 05 00 8b ce e8 6b f8 ff
Stack dump:
008eac0c 00000000 0044bac3 008fe594 008fe578 00fffbf4 0044c6cb 008fe590 00fffc0c 0044c660 008fe590 008fe470 008fe578 008e907c 00fffc48 0044c3a8

This sounds like the source of at least one of the types of reported intermittent failures. Inability to deal with long streams of repeated IR data.